Python liberary/Utility to generate A/C IR signals

Project description

#pyhvac

THIS IS WORK IN PROGRESS

LG is not tested. "auto" mode for Sharp J-Tech is flaky

pyhvac is a Python 3 library/utility to generate IR code for A/C device.

This library uses code/work from:

Installation

We are on PyPi so

 pip3 install pyhvac
 or
 python3 -m pip install pyhvac

 After installation, the utility

 gaccode, gcpanasonic, gcdaikin, gclg, gcsharp

 can be used to generate codes. Use the -h option for help.

 Note that the utilities cannot fully excersise all the capabilities of their respective plugin.
 For instance, the code for a Sharp A/C can depend on the state of the device. gcsharp does not keep track of the
 state of the device.

Library

pyhvac uses plugin to add support.

Each plugin file must have a

   PluginObject

class that must have a "get_device" method to return HVAC objects, a 'brand' attribute and a 'models' attribute containing a dictionary matching models to objects. Note that brand and models MUST BE lowercased.

Each HVAC object describes a specific way of generating codes for IR transmission.

The codes should be returned as a list of bytes in either lsb or msb format. The HVAC object must have its "is_msb" attribute set to False or True accordingly.

All HVAC objects are required to have at the minimum 2 capabilities:

mode   with at least "off" and another value ("auto", "cool", ....)
temperature  with the accepted range

Other capabilities are expected.

To simplify things, it is requested that some sort of normalization of function names occur. In most cases an AC unit will have the following

mode: the operating mode. Values are expected to be amongst
      "off"   turned off (This is mandatory)
      "auto"  automatic mode sometines known as "feel", "ai", ...
      "cool"  Cooling
      "heat"  Heating
      "dry"   dehumidifying
      "fan"   fan mode only

temperature:  The full range of temperatures. If there
              are 2 distinct ranges for cooling or heating,
              the union should be used here.

              The attribute 'temperature_step' can be used to
              specify fractioanl temperature e.g. 0.5, 0.1


fan: The air flow power. Values are expecterd to be amongst
       "auto"   Automatic mode
       lowest   The lowest air flow setting
       low
       medium
       high
       highest

       When there are only 3 modes, highest, medium and lowest should be used if possible

swing: The use of the vertical orientation of the air flow..
        It can be a switch on/off (values 'off' and 'on') or more complex

        auto  automatic (in many cases similar to the on/off switch function)
        90    Horizontal orientation
        75
        60
        45
        30
        15
        0     Vertical orientation

Many other functions are possible, but still some canonization is recommended.

For instance, many manufactures trademarked their air purifying techonlogy: nanoe, nanoex (Panasonic), plasmacluster (Sharp), plasma (LG).... In this case it is recommended to use the name "purifier" for that functionm

The HVAC object offers to convenience methods: to_lirs, to transform the frames into lirc codes to_broadlink, to trnaform the frames into Broadlink compatible codes

TO BE CONTINUED

Project details


Download files

Download the file for your platform. If you're not sure which to choose, learn more about installing packages.

Source Distribution

pyhvac-0.0.3.tar.gz (16.2 kB view hashes)

Uploaded Source

Built Distribution

pyhvac-0.0.3-py3-none-any.whl (25.0 kB view hashes)

Uploaded Python 3

Supported by

AWS AWS Cloud computing and Security Sponsor Datadog Datadog Monitoring Fastly Fastly CDN Google Google Download Analytics Microsoft Microsoft PSF Sponsor Pingdom Pingdom Monitoring Sentry Sentry Error logging StatusPage StatusPage Status page